  Equipment will inevitably have problems during use, so in order to prolong the service life of the equipment,regular maintenance and maintenance are required, and reverse osmosis equipment is the same. So what are the common faults of reverse osmosis equipment? What is the workaround? Let's find out together.


1. Blockage of the membrane


  First of all, the most likely failure of reverse osmosis seawater brackish water desalination equipment is the blockage of the membrane. The reason for this problem is mainly because the pre-filter has not been replaced or cleaned for a long time, resulting in the water quality inside the machine is far worse than the water quality before entering the machine. The quality of the raw water is poor, and the proportion of wastewater is small, which causes the blockage of the wastewater solenoid valve or the flushing combination valve, and then no wastewater or very little wastewater is discharged, which leads to the blockage of the membrane and the shortened service life of the purified water equipment. . The solution is to replace the reverse osmosis membrane regularly.


2. The transformer is faulty


Reverse osmosis equipment  in addition to the failure of membrane blockage, there is also a relatively common problem, that is, the failure of the transformer. If there is a problem with the transformer, it will not be able to provide the voltage required for the normal boosting of the pump, the speed will be slow, the increased pressure will be small, and the increase in If the pressure is small, the pressure required for the tap water to pass through the RO membrane will naturally not be reached, and the water production will be slow at this time. The solution is to find a professional for overhaul first. After eliminating the main factors that affect the slow water production, such as the pump factor and the membrane factor, it is necessary to replace the transformer with a new one.


3. The filter element is blocked


  Clogging of the filter element is also one of the common faults of purified water equipment. The reason for the blockage of the filter element is that the secondary pollution of tap water is becoming more and more serious. If the pipeline is old, the filter element can be said to be blocked. In industrial production, if there is a lack of dedicated maintenance, the filter element is rarely replaced, so clogging is common. Solution: Replacing the filter element is very important to prolong the life of the equipment, and personnel should be arranged to maintain and replace it regularly to ensure that it is unobstructed.